UAN: +923-111-141-222 info@brightway.pk
COVID-19 UPDATE We are open with limited hours and staff.
-32%Sold out

SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation - SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation Price in Pakistan

Rs.250,000.00 Rs.170,000.00

Shipping calculated at checkout.
People are viewing this right now

SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation - SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation Price in Pakistan   Brief introductionMs100 spo2 simulator is a kind of separated spo2...

Notify me when this product is available:

SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation - SPO2 Simulator, Pulse Oximeter Simulation, Oxygen Saturation Simulation Price in Pakistan

 

Brief introduction
Ms100 spo2 simulator is a kind of separated spo2 simulator, small and lightweight. It can carry out a series of tests for the oximeter by means of simulation means and gives knowledge of the veracity of the oximeter.
Since the oximeter manufacturer can use different R-curves, some R-curves used abroad have currently been embedded.


Disconnected connection between simulator probe and host, operation and test are more convenient.
◆ 262k color and 320*240 tft, adjustable brightness.
◆ Press film button, makes the operation more convenient.
◆ Power supply with rechargeable lithium battery, can display the charging information of the battery.
◆ Key volume, can open or close.

Main functions
◆ Oxygen saturation simulation;
◆ Pulse rate simulation;
◆ Patient condition simulation before set;
◆ Can test the response time of the device;
◆ Can simulate the spo2 and pulse rate under different amplitudes;

◆ Can test the performance of the device under different interference source;
◆ Can select different r-curve.

Main parameters

◆ Spo2
measuring range: 35%~100% Resolution: 1% Error: If spo2 is 75%~100%, the error is greater between ± 2%

and ± p (p denotes the precision of the tested oximeter); if spo2 is 74%~50%, the error is greater between ± 2% and ± p; no definition if spo2 is less than 50%.
◆ Pulse rate
measuring range: 25bpm ~ 250bpm Resolution: 5bpm error: 1% ± 1bpm


◆ Amplitude


measuring range: 0.000%~20,000% resolution: 1% for 1,000%~20,000%
; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
◆ Patient condition
24 conditions pre-set and 8 conditions as standard after startup. The number of conditions can be adjusted by motion plane setup.

◆ Voltage

DC 3.6V~4.2V. ◆ Power supply

voltage 3.7 Rechargeable lithium battery × 1
◆ Battery
life charge and discharge not less than 500 times.

Accessories

◆ One MS100 User Manual
◆ One 5.0V Adapter



Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Browse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order Note Edit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

Coupon code will work on checkout page